| MIL-M-63995 (AR)
TABLE II.
Functional firing.
Total Required
Round Number
Siimulated Elevation
Recoil Mode
Rod Pu1l (lbs]
0
0
1
Long
Final Warm Up
(-)0
2
Long
126,000 Max.
Maximum
3
Short
212,000 Max.
Maximum
4
Short
212,000 Max.
0
0
5
Long
126,000 Max.
TABLE
III. Recoperator nitrogen pressure.
Cannon
Nitrogen
Pressure
M113/M113A1
2300 25
M2A2
1900 25
M201
2300 25
4.7.4 Proof firinq. Mounts selected as specified in 4.5.1
shall be proof fired as specified in Table IV. Recuperator
nitrogen pressure shall be set at 2300 25 psig prior to firing.
All measurements required by 3.4.3 shall be recorded for each
firing. Hydraulic pressure supplied to the gun mount shall be
2750 + 100 psig. If a M110 vehicle is used, both traversing and
elevating drive assembly slip clutches shall be adjusted per TM
9-2300-216-34.2. All measurements required by 3.4.3 shall be
recorded for each firing. Observation shall be made for erratic
motion in counter recoil. After firing, each mount shall be
examined to determine compliance with oil leakage requirements
specified in 3.4.5.