| MIL-M-70453A(AR)
2.3 Order of precedence. In the event of a conflict
between the text of this document and the references cited herein
the text of this document takes precedence. Nothing in this
document, however, supersedes applicable laws and regulations
unless a specific exemption has been obtained.
3.
REQUIREMENTS
3.1 Materi als. Materials shall be in accordance with the
applicable drawings and specifications.
Comp onen ts and assemblies. The components and
3.2
assemblies shall comply with all requirements specified on
Drawing 9360169, all associated drawings, and with all
requirements specified in applicable specifications and
standards. Where applicable, the mount shall meet the
requirements of MIL-F-13926 as follows:
Dimensions and tolerances.
a.
b.
Inorganic protective surface finishings.
c.
Part identification and marking.
workmanship.
d.
Prospective bidders should be
3.2.1 Radioactive material
cognizant of the need for a Nuclear Regulatory Commission License
governing the procurement possessing, handling, and shipping of
radioactive material.
Any mount subjected to any or all of
3.3 Environmental.
the requirements of 3.3.1, 3.3.2, 3.3.3.1, and 3.3.3.2 inclusive,
shall subsequently meet the requirements of 3.5 to 3.7.5
inclusive, unless otherwise specified.
3.3.1 vibration. The mount shall be vibrated at 30 + 5
cycles per second frequency with an amplitude of 1/16 inch (1/8
inch maximum excursion) for a period of five minutes + 15
seconds. Orientation of the mount shall be in accordance with
4
|