|
| MIL-M-81260A(AS)
so that the entire diagram is fully visible when the manual is closed on the extended
foldout. This requirement shall not apply to wiring diagram manuals, partial page
presentations, when all text relating to the illustrations appears on a single page
or when diagrams are contained in a separate manual.
3.2.3.2.2
Type s of Diagrams. - The following types of diagrams
shall be furnished as applicable:
a.
Functional flow diagrams including block, semi-block,
and logic diagrams.
b. Schematic diagrams.
Others as approved by the procuring activity.
c.
3.2.3.2.2.1
Functional Flow Diagrams. - Functional flow diagrams shall
be included to the extent necessary for an understanding of the data flow within a
system, subsystem, or component and its interaction with other systems or systems
elements (see figures 1 through 6).
3.2.3.2.2.2
Schematic Diagrams.
3.2.3.2.2.2.1
Single Schematic Diagrams. - Where the nature of the
equipment, relative complexity, and number of components make it practicable,
a single schematic diagram shall be prepared to cover all components of the
equipment covered in the manual(s).
3.2.3.2.2.2.2
Separate Schematic Diagrams. - When a single diagram is
not practicable, a separate diagram shall be prepared for each component or
subgrouping of components. Interconnecting points for components covered in
separate diagrams shall be identified. For example: circuits requiring contin-
uation to other diagrams and which terminate with a plug, terminal strip, jack,
etc., shall show a composite plug grouping. Each lead shall be extended through
the plug, terminal strip, jack, etc., and labeled to indicate the necessary desig-
nator of the first connection within the other component or other significant
point of termination.
3.2.3.2.2.2.3
Component and Subassembly Identification. - When the
equipment is covered by a single schematic diagram, individual components shall
be identified by a series of broken lines forming a rectangle or closed box. When
separate diagrams of components or subgroups of components are prepared, sub-
assemblies shall be identified by a series of broken lines forming an enclosure.
5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |