MIL-M-82433A(OS)
Table VI (Cont'd)
Test Equipment
Identification
Item
As shown in
Power switching circuit (to operate motor in
Figure 4.
either direction under manual control.  Voltage
at motor shall have a step waveform with rise
time less than 100 microseconds).
DC power supply (regulated, variable voltage,
15 to 42 volts, O to 10 amperes (minimum).
The effective source impedance shall not exceed
0.02 ohm).
Vacuum tube voltmeter (de), O to 1.0 vdc;
Input resistance:  greater than 50 megohms;
Accuracy:
3 percent.
As shown in
Commutation noise test circuit
Figure 6.
Tektronix
Oscilloscope (precision, dc coupled, with vertical
Model 531
amplifier response to several megacycles and with
with plug
calibrated sweep rates accurate within 2 percent.
The range 2-5 milliseconds per centimeter is of pri-
in pream-
plifier
mary interest.  Sweep triggering facilities are
necessary. )
Type A
Megohmmeter (200 vdc potential, reading
accuracy within 5%.)
Simpson
Ohmmeter
Model 269
or equivalent
4.7.3 Test procedure.  The following tests shall be performed on
each motor to be delivered:
(a) Insulation resistance of windings (4.7.3.1)
22