Type of Meter
Unit
MS
17322
RT-1022/ARN-84(V)
MS
17322
CV-2837/ARN-84(V)
MS
17322
RT-1127/ARN-84(V)
MS
17322
CV-3134/ARN-84(V)
MS
17322
CV-3135/ARN-84(V)
MS
17322
CV-3136/ARN-84(V)
Cabling and Connections
3.3.3
Cables and Connectors - The equipment shall
3.303.1
provide for the use of cables and connectors in accordance with
Specification MIL-E-5400.
Interconnections Cabling - The equipment shall
3.3.3.2
be capable of satisfactory operation using external wiring in
accordance with the applicable requirements of specification MIL-
W-5088. The external wiring shall be unshielded, except that a
minimum number of the individual wires may be shielded when
demonstrated as necessary to need interference control
requirements and provided the assembly of the cable to its plugs
may be easily accomplished. External cables and that portion of
the connectors attached to the cables shall not be supplied as
part of the equipment.
Control Panels - All rack ox console mounted
3.3.4
control panels shall conform to the applicable requirements of
Specification MIL-C-6781. The configuration of all panels must be
approved by the procuring activity prior to preproduction testing.
Interchangeability
3.3.5
Electrical and Mechanical - The equipment shall
3.3.5.1
meet the interchangeability requirements of Specification MIL-E-
54000
Adjustments - There shall be no adjustments to
3.3.5.2
permit interchange of modules.
Interference Control - The generation of radio
3.3.6
interference by the equipment and the vulnerability of the
equipment to radio interference shall meet the requirements of
MIL-STD-461, except as modified herein.