| MIL-N-81207A(AS)
Room ambient (25C5C)
Temperature
Normal Ground
Altitude
None
Vibration
Room ambient up to 90%
Humidity
relative humidity
Input power voltage 1151.O VAC, 27.50.5 VDC,
and 26.00.5 VAC
Service Conditions - The equipment shall
3.3.10
operate satisfactorily under any of the environmental service
conditions or reasonable combination of these conditions as
specified in Specification MIL-E-5400 for Class 2X equipment,
except as modified herein.
Vibration - The equipment shall operate
3.3.10.1
satisfactorily when subjected to the vibration requirements of
Curves IV and II of Specification MIL-E-5400. The Navigation Set
Controls shall conform to Curve I except the amplitude shall not
exceed 5g.
Warm-Up Time - The time required for the
3.3.11
equipment warm-up prior to operation shall be kept to a minimum
and shall not exceed 2 minutes under standard conditions and 6
minutes at extreme service conditions.
Input Electrical Power
3.3.12
Operating Power - The equipment shall meet all
3.3.12.1
applicable requirements of MIL-STD-704 and shall give specified
performance when energized from the following power sources having
characteristics and limits as defined in MIL-STD-704. The power
required shall not exceed the specified amounts.
(1) AC Power (Single Phase),
Category B
300 watts
115 volts,REC Mode
300 watts
T/R Mode
335 watts
A/A Mode
350 watts
BCN Mode
(2) DC Power,28V, Category B, 3.2A
Lighting Power - Input power for lighting shall
3.3.12.2
require not more than 8 watts at 28 volts DC for the C-8734/ARN-
84(V), not more than 4 watts at 5 volts DC for the C-9054/ARN-
84(V) or for the C-9475/ARN-84(V) or for the C-9483/ARN-84(V).
11.
|