MIL-N-81207A(AS)
Contents - The Base shall contain the following
3.5.14.4
assemblies:
(1) Mounting Base
(2) Four Shock Isolators
(3) Six electrical connectors
Controls and Indicators - The Base shall not
3.5.14.5
contain any controls or indicators.
Electrical Confections - The electrical
3.5.14.6
connections shall be in accordance with Figure 19.
Base, Shockmount, Electrical Equipment
3.5.15
MT-4617/ARN-84(V) - The Base shall meet the applicable
requirements of MIL-C-172.
Function - The Base shall provide suitable
3.5.15.1
mounting provisions for the Receiver-Trasmitter RT-1127/ARN-84(V)
and Signal Data Converter CV-3136/ARN-84(V), and shall provide for
electrical connections.
Form Factor - The form factor of the Base shall
3.5.15.2
be in accordance with Figure 20.
Weight - The weight of the Base shall not
3.5.15.3
exceed 8.0 pounds.
Contents - The Base shall contain the following
3.5.15.4
assemblies:
(1) Mounting Base
(2) Eight Shock Isolators
3.5.15.5 Controls and Indicators - The Base shall not
contain any controls or indicators.
Electrical Connections - The Base shall not
3.5.15.6
have any electrical connections.
Design Data - No data is required by this
3.6
an reports accompanying samples submitted
specification (other
for testing) or by applicable documents, unless specified in the
contract or order.
54.