| ![]() MIL-N-81604C(AS)
TABLE II.
EQUIPMENT CABLE LENGTHS
Signal Transmission
Cable Length (Maximum)
1.
ANCU to IMU
60 feet
2.
ANCU to CIU
60 feet (see notes)
3.
ANCU to ASW-27
60 feet
4.
ANCU to ASW-25
20 feet
5.
ANCU to CAU
60 feet
IMU to CAU
6.
60 feet
7.
IMU to XAS-1233 Test set
15 feet
8.
PSU to IMU
60 feet (see notes)
9.
PSU to ANCU
60 feet (see notes)
NOTES
1.
The power connectors shall contain a sufficient
number of pins to allow transmission of power
over uniform continuous cables up to 30 feet in
length.
2.
Power transmission over cables longer than 30
feet shall be accomplished by the use of air-
craft cabling techniques which provide imped-
ances no greater than the continuous 30 foot
cables described in note 1. For example, a
transition to a larger wire size or an in-
creased number of wires may be used for cables
longer than 30 feet.
3.3.3.3 Unit Interconnection - Figure 1 identifies the connectors,
signal interconnection, and pin assignments of the equipment.
3.3.3.4 Internal Wiring - The use of wire wrap solderless
connections shall meet or exceed the requirements of and be in
accordance with MIL-STD-1130, Class A and CODE IDENT 10001
*
NAVORD WS 6118 and WS 6119.
8
|