| ![]() MIL-N-81604C(AS)
Para 3.3.11 (cont)
For shore-based operational aircraft conditions, the
b.
alignment time shall be less than 8 minutes under all
ambient temperature conditions down to -65F.
For laboratory test conditions, the alignment time
c*
shall not exceed 5 minutes where the ambient temper-
ature is 0F or above.
3.3.12 Input Electrical Power
3.3.12.1 Operating Power - The equipment shall meet all applicable
requirements of MIL-STD-704 and shall give specified performance
when energized from the following power sources having character-
istics and limits as defined in MIL-STD-704. The aircraft power
required shall not exceed the specified amounts:
IMU
AC Power (single phase), 115V, Category B, 1.5 VA,
a.
Power Factor >0.9
AC Power (three phase), 115/200V, Category B,
b.
1987 VA, Power Factor >0.9
AC Power (single phase), 26V, Category B, 6VA,
c.
Power Factor >0.25
Psu
AC Power (single phase) , 115V, Category B, 90 VA,
a.
Power Factor >0.9
AC Power (three phase), 115V, Category B, 810 VA,
b.
Power Factor >0.9
ANCU
AC Power (single phase), 115V, Category B, 1.5 VA,
a.
Power Factor >0.9
AC Power (single phase), 26V, Category B, 0.2 VA,
b.
Power Factor >0.25
CIU
AC Power (single phase), 115V, Category B, 1.5 VA,
a.
Power Factor >0.9
17
|