Click here to make tpub.com your Home Page

Page Title: Performance Check
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-N-81857(AS)
Quantity to be Selected
Q u a l i t y of Equipments
for Life Test
O f f e r e d for Acceptance
1
First 25
1
Next 175
1
Next. 300
1 for each additional 500
o r fraction thereof.
4.5.1
T e s t C o n d i t i o n s - The life test shall be conducted
under the following simulated service conditions.
Temperature
Normal Room
Altitude
Normal ground (0 - 5000 ft.)
Humidity
Room
ambient
115 5 volts (at lowest
A. C. Voltage
a p p l i c a b l e frecluency)
2'7.0 2.0 volts
D. C. Voltage
4.5.2 T e s t P e r i o d s - The test may be run continuously
or intermittently. Any period of operation shall be of sufficient
d u r a t i o n to permit the equipment temperature to stabilize. Periodi-
c a l l y , the equipment shall be turned on and off several times and
p u t through its various phases of operation.
P e r f o r m a n c e Check --  A t approximately 8-hour
4.5.3
intervals during the test, a limited performance check shall be made.
T h e performance check proposed by the contractor shall be subject
to approval by the procuring activity.
Test Data -  The contractor shall keep a daily record
4.5.4
of the performance of the equipment, making particular note of any
d e f i c i e n c i c s or failures.  In the event of part failures, the defective
part shall be replaced and the operation resumed for the balance of
the test period.  A record shall be kept of all failures throughout the
t e s t .  This record shall indicate the following:
43

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business