MIL-O-52374D
i. All meters used during tests shall have been calibrated within 30 days of the start of testing, and
thereafter as required and at intervals not to exceed 6 months. All meters shall be accurate within
1.0 percent of full scale reading, except the meter used to measure V1 which shall be accurate within
0.5 percent of full scale reading.
NOTES:
1. C1 Approximately 40 pF nominal, select for 55 pF total load on oscillator.
2. Multiplier to apply not more than 16 kV to the image converter tube.
3. Capacitors used in the multiplier doubler circuit shall have a minimum capacitance of 1,000 pF.
FIGURE 4. Oscillator test circuit.
12