(k) - Endurance tests, high-impact shock tests, and non-destructive
tests (if performed) and the design review agency letters
approving these reports or extension of any tests.
(l) Overall dimensions of the complete unit including locating of
all fittings and connections, the space required for removal
and replacement of parts for maintenance, and mounting
information.
(m) The certification by the mechanical seal manufacturer required
by 3.3.7.8.
3.6.1.2.4.3 The pump performance chart included on the certification
data, outline drawing, or both shall include performance curves depicting
gal/rein, feet head, efficiency, and brake hp for various impeller diameters to
provide Navy field activities with impeller trim data. Sufficient performance
curves shall be shown to provide impeller trim data for head capacities included
within the total rating boundary for the pump show on figures 6 and 7.
3.6.1.2.4.4 All drawing shall include in the title block the designation
"Navy Standard Close-Coupled Pump, SPCC Identification_______________________."
This identification is developed from the following sample
NOTE:
symbol system:
Permissible symbols are as follows:
Pump size - as required by contract
1.
R/rein - as required by contract
2.
HP - as required by contract
3.
4.
Voltage - A = ac
d = dc
1 = 115-volt
2 = 230-volt
4 = 440-volt
Maximum head capacity pump - always MHC
5.
Special feature, if applicable - AS - abrasive separator
6.
N M - nonmagnetic
3.6.1.2.4.5 Drawing content for electric motors shall be in accordance
with MIL-M-17060 for Navy service A.
3.6.1.2.5 On board repair parts list. A list of on board repair parts
shall accompany the outline drawings. This list shall be
provisioning list forms in accordance with MIL-P-15137. This list shall be
furnished whether or not the parts are required in the pump contract or order.
This list shall not be modified to indicate parts or quantities of parts
24
|