| MIL-P-46601B (MU)
4.4.3 (Cont)
Major or
Minor
Minor
Major
Critical
Defect and Method of Inspection
No.
Anvil (Cont)
x
No vent holes
35
x
Laminated metal
36
x
Ringed
37
x
Unsymmetrical vent holes
38
Foil
x
Partial
39
x
Stained
40
Pellet
x
41
Heavy
x
Light
42
Gaging Primer
X
Diameter
43
Excess ellipticity between long and
44
x
short axis diameters
x
Height
45
1/ Refer to ORD-SIP-S314 for visual defect standards for defects 1 through 40.
4.4.4 Tests.-Tests listed in Table II shall be performed on each primer
lot sample in accordance with the test methods prescribed in 4.5. Sample
size and acceptance criteria for each test shall be as specified. Only
primers which have met the visual and dimensional requirements shall be
used in the ballistics tests,selected in such a manner that the sample
is representative of the entire lot. The primers selected shall be
thoroughly mixed before being divided into samples for the various tests.
TABLE II
Rqmt Para
Sample Size
Test
3.3
400
1/
Sensitivity
3.4
50
2/
Action time
200
3.5
3/
Function and casualty
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |