40.2.6 Output capacitor voltage. The voltage on the output
capacitor shall be measured by connecting the S.U.T. as shown in
Figure 8.
Capacitor present - with SW1 open apply power and verify that
A.
rises to the limits specified in Table I. Take this
measurement 1 second after power on.
B. Capacitor Leakage - Close SW1 until
= 3.3 volts, then open
14 seconds minimum then measure
Sw1 . Upon opening SW1 wait
must be greater than the value specified in Table I.
Output capacitor voltage measurement.
FIGURE 8.