| ![]() MIL-P-48450A(MU)
NOTE: The tests in Table I shall be conducted at a temperature
between +60 and +90F.
4.3.3 Acceptance and rejection.- Rejected lots shall be screened
for all defective characteristics. Removal or correction of defective
units and resubmittance of rejected lots shall be in accordance with
"Acceptance and Rejection" as specified in MIL-STD-105.
4.4 Special sampling
4.4.1 General.- One periscope shall be selected at random as a
special sampling from each 100 produced. the sample shall meet the
requirements and tests in Table II.
TABLE II
TEST PROCEDURE
REQUIREMENT
NO l
CHARACTERISTIC
Applicable drawings
3.1
Fabrication
301.
and specifications -
visual
MIL-F-13926 - visual
3.3
General specification
302.
4.4.1.1 Three periscopes that have met the requirements and tests
in 4.3.2.2 and in Table. I shall be selected at random as a special sample
from each months production. Each sample shall then meet the require-
ments and tests in Table III.
TABLE III
TEST PROCEDURE
REQUIREMENT
No l
CHARACTERISTIC
Interchangeability,
303 l
4.6.5.1
3.2a
modules
4.4.1.2 Environmental.- Three periscopes shall be selected at random
as samples from each 50 produced, or from each months production, whichever
occurs first. Each sample shall meet the requirements and tests in Table
IV and shall then meet the requirements and tests in 4.3.2.2 and in Table I.
TABLE IV
TEST PROCEDURE
REQUIREMENT
NO.
CHARACTERISTIC
Storage temperature
304 l
4.6.1.1
3.4.1
(-80 and +160F)
Operating temperatures
305.
4.6.1.2
3.4.2
(-40 and +150F)
Operability, elevation input
306.
4.6.1.2, 4.6.2.1
3.4.2, 3.6.10.1
coupling
Operability, diopter movement -
307.
4.6.1.2, 4.6.2.2
3.4.2, 3.6.10.2
Daylight and Passive
Operability, focusing
308.
4.6.1.2, 4.6.2.3
3.4.2, 3.6.10.3
mechanism Passive