| MIL-P-48619(AR)
TABLE IV - CLASSIFICATION OF DEFECTS
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
NO.
4.6.7.1
3.2a
Interchangeability,
303.
Modules
The tests in Table IV shall be conducted at a temperature of
NOTE:
730 18F.
4.5.3 Environmental. -Three periscopes shall
be selected at
random as samples from each 50 produced, or from
each month's
production, whichever occurs first. Each sample
shall meet the
requirements and tests in Table V and shall then
meet the require-
ments and tests in Tables I and II.
TABLE V - CLASSIFICATION OF DEFECTS
TEST PROCEDURE
REQUIREMENT
NO.
CHARACTERISTIC
3.4.1
4.6.1.1
304. Storage temperature
(-80 and +160F)
3.4.2
4.6.1.2
305. Operating temperatures
(-40 and +150F)
3.4.2, 3.5.1
4.6.1.2, 4.6.2.1
306. Operability, elevation input
coupling
3.4.2, 3.5.2
4.6.1.2, 4.6.2.2
307. operability, diopter move-
ment, Daylight and Passive
3.4.2, 3.5.3
4.6.1.2, 4.6.2.3
308. Operability, focusing mechanism
Passive
3.4.2, 3.5.4
4.6.1.2, 4.6.2.4
309. Operability, disengagement of
boresight knob locks - Daylight
and Passive
3.4.2, 3.5.5
4.6.1.2, 4.6.2.5
310. Operability, rotation of bore-
sight knob - Daylight and
Passive
3.4.2, 3.5.6
4.6.1.2, 4.6.2.6
311. Operability, shutter lever and
on-off switch - Passive
3.4.2, 3.5.7
4.6.1.2, 4.6.2.7
312. Operability, gain adjust and
reticle brightness control -
Passive
3.4.2, 3.5.8
4.6.1.2, 4.6.2.8
313. Operability, focusing lock -
Daylight
3.4.2, 3.5.9
4.6.1.2, 4.6.2.9
314. Operability, objective focus
ing mechanism - Daylight
NOTE:
The tests for characteristics 306 through 314 inclusive,
0
shall be conducted at -40 and +150F.