Click here to make tpub.com your Home Page

Page Title: Focusing mechanism - Passive
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-P-48619(AR)
4.6.2.3 Focusing mechanism - Passive. -Standard torque measuring
equipment capable of measuring the torque values specified in 3.5.3
shall be utilized for this test.  An appropriate adapter to accom-
modate Ring 11733436 shall be used with the torque measuring equip-
ment. Torque shall be measured while rotating the ring through the
range specified in 3.5.3.  The running torque required to rotate
Ring 11733436 shall conform to the applicable requirements of 3.5.3
for the temperatures indicated.
4.6.2.4 Disengagement of boresight knob locks - Daylight and
Passive. -Standard measuring equipment capable of measuring the force
values specified in 3.5.4 shall be utilized for this tests  The
force required to disengage each boresight knob from the lock
position shall conform to the applicable requirements of 3.5.4 for
the temperatures indicated.
4.6.2.5 Rotation of boresiqht knobs - Dayliqht and Passive. -
Standard torque measuring equipment capable of measuring the torque
values specified in 3.5.5 shall be utilized for this test. An
appropriate adapter to accommodate the boresight knobs shall be used
with the torque measuring equipment. Torque shall be measured while
rotating each boresight knob through the range specified in 3.5.5.
The running torque required to rotate each boresight knob shall
conform to the applicable requirements of 3.5.5 for the temperature
indicated.
4.6.2.6 Shutter lever and on-off switch - passive. -Standard
torque measuring equipment capable of measuring the torque values
specified in 3.5.6 shall be utilized for this test.  The torque
required to rotate the shutter lever from the off to on position and
then back-to the off position shall conform to the applicable
requirements of 3.5.6 for the temperatures indicated.
4.6.2.7 Gain adjust and reticle brightness control - Passive. -
Manually operate the knob MS91528-OEIB.  The knob shall meet the
requirements specified in 3.5.7, at the temperatures indicated in
0
3.4.2 in addition to the standard ambient temperature (73 18 F).
4.6.2.8 Focusing lock - Daylight. -A torque wrench capable of
applying the specified torque values in 3.5.8, together with a
standard type driver bit that properly fits the screw slot of the
locking screw and eccentric, shall be utilized for performing this
test.  With the specified torque applied to the locking screw and
while observing the eccentric, apply in a clockwise direction, the