MIL-P-60335C (MU)
4.3.4.1 (government rights to documentation.-Inspection
equipment drawings and lists provided and revised in
accordance with the requirements of the ET may be used by DOD
activities for design, procurement manufactures testing,
evaluation, production and receiving inspection, overhaul,
shipping, storage, identification of stock, ordering and storage
of replacement parts, inspection of items at overhaul,
general maintenance of equipment, construction, survey and
whenever inspection equipment drawings are needed.
4.3.4.2 Supply and maintenance.-Supply and maintenance
of the equipment listed in the ET shall be in accordance with
Specification MIL-I-45607.
4.3.4.3 Government use of contractor's Inspection
equipment.-The contractor shall make available to the Government
all inspection equipment necessary for determining conformance
with contract requirements.  Personnel for operating the
equipment and verification of Its accuracy, shall be supplied
by the contractor for the performance of examination or test
by the Government.
4.4 Test methods and procedures
4.4.1 Moisture
4.4.1.1 First fire composition.-The moisture content of
the first fire composition shall be determined in accordance
with Standard MIL-STD-1234, Method 101.3.  The special solvent
to be used shall be equal parts by volume of trlchloro ethylene
and anhydrous methanol.
4.4.1.2 Illuminant composition.-The moisture content of
the illminant composition shall be determined in accordance
with the Karl Fischer Method as stated in Standard MIL-STD-1234,
Method 101.2, up to paragraph 5.3,  A 50 milliliter (ml.) sample
of 1:1 dimethylformamidemethyl alcohol solution shall be added
into a 250 ml. Erlenmeyer flask (fitted with a rubber stopper)
containing 10 grams (g) Of the pyrotechnic sample.  (Exercise
care to exclude atmospheric moisture).  The flask shall be
stoppered and shaken vigorously to thoroughly mix solution and
pyrotechnic sample.  Allow the solution to set 5 to 15 minutes.