| MIL-P-62211B(AR)
TABLE III. Power transient and +15V interlock.
3.4 Enviromental.
3.4.1 Shock. The assembly shall be capable of operating as specified
herein after esposure under the conditions of 3.1.3 to three half sine wave
shock pulses of 40 4 gravity units (g) for a duration of 18 3 milliseconds
(mset) applied in each direction along three mutally perpendicular axes. In
addition, the assembly shall be capable of withstanding three half sine wave
shock pulses of 100.0 10.0 g for a duration of 1.5 0.2 msec applied in
each direction alomg three mutally perpendicular axes. (See 4.6.3.1)
3.4.2 Vibration. The assembly shall be capable of operating as specified
herein after exposure under the conditions of 3.1.3 to the vibration profile
of figure 4. Duration of exposure shall be not less than 80 minutes in each
of three mutally perpendicular axes. (See 4.6.3.2)