| MIL-P-62211B(AR)
4.6.3.4 Low temperature. Use item 5 and 6 of table VII a suitable
equipment and subject the assembly to the loW temperature test specified in
MIL-STD-810, method 502.1, procedure 1. The storage temperature shall be
-65F. The lowest operating temperature shall be -25F. The performance
tests of table IV shall be applied.
4.6.3.5 Temperature cycling. With power and loads of table I applied,
subject the seembly to the temperature profile specified in figure 5. At the
conclusion of this test, subject the assembly to the performance tests of
table IV.