4.8.4.7 Relay operations.
4.8.4.8 Transient voltage characteristics. TO determine conformance to
3.5.7, the power supply shall be used to apply 1.0 0.5 mA through a 2.4 K
10% ohm resistor to the positive and ground pins specified in 3.5.7. With a
multimeter verify that the voltage from the positive to the ground pin is 39
3 V dc.
4.8.4.9 Time delay and latching circuit (Class 2). To determine
conformance to 3.5.8, utilizing power supply, apply 24 6 V dc through an
MS25237-387 test lamp to P1-28, and to a second MS25237-387 test lamp to
P1-12. Connect the power source to P1-19 and the power source return to
P1-15 for a 10 2 second period. Verify that the two lamps do not
illuminate. Connect the power source to P1-27 (for a 5 1 second periods
and the power source return to P1-15. Verify that the two test lamps
illuminate and remain illuminated. Interrupt the power source and verify
that the two test lamps extinguish.
4.8.4.10 Fire warning circuit.
Not applicable.