| MIL-P-82436(OS)
4.6.1
Test conditions. Unless otherwise specified, the pump shall
be subjected to the periodic tests under the following conditions:
Temperature:
Room ambient +32 F to +98 F
Altitude:
Normal ground atmospheric
pressure
Vibration:
None
Room ambient
Humidity:
4.6.2
Test equipment and set-up. The test equipment and set-up for
the periodic tests shall be in accordance with 4.4.3.
4.6.3
Test procedures.
Vibration, ready condition. Vibration testing of the pump, in
4.6.3.1
the ready condition, shall be performed in accordance with 4.4.4.2.
4.6 .3.2
Acceleretion, ready condition. Acceleration testing of the
pump, in the ready condition, shall be performed in accordance with 4.4.4.3.
4.6.3.3
Shock, ready condition. Shock testing of the pump, in the
ready condition, shall be performed in accordance with 4.4.4.4.
Temperature
4.6.3.4
Temperature and humidity, non-operating condition.
and humidity testing of the pump, in the non-operating condition, shall be
performed in accordance with 4.4.4.5.
High temperature operating. The pump shall be subjected to the
4.6.3.5
high temperature operating test in accordance with 4.4.4.7.
Low temperature operating. The pump shall be subjected to the
4.6.3.6
low temperature operating test in accordance with 4.4.4.6.
4.6.3.7
Operational test. The pump shall be subjected to the opera-
tional test in accordance with 4.4.4.1.
4.6.3.8
Operational service life. The pump shall be subjected to 6
additional operational tests in accordance with 4.4.4.1.
21
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |