MIL-Q-48555A(AR)
4.6.3.1 Inspection after retest.  Inspection of the sample
after retest shall be conducted by the Government and shall be in
accordance with 4.3.2.2, "Final Acceptance Inspection", except
characteristics 101 of Table 1, 301 and 302 of Table II.
Reappearance of the previous defect 4.6.2, may be cause for the
Government to prescribe mandatory process corrective action by the
Contractor at no additional cost to the Government.
4.7 Methods
of
inspe ction.
--.
4.7.1 Performance.
4.701.1  orientation.  Final inspection fixture 11747194 and
inspection aid 8658940 shall be used for inspection of the quadrant.
The inspection  fixture shall be pOSitiOned  on  a  vibration  free
surface  and  set-up  in  accordance  with  the  set-up  instructions
Subsequent  to
contained  on  the inspection
fixture
drawing.
completion of all set-up and mounting instructions, the quadrant
shall be oriented as specified in 3.9 of this specification.
4.7.1.2 Excursion
range.
4.7.1.2.1  Elevation  counter.  With the elevation counter
indicating "OOO MILS", the elevation counter knob shall be manually
rotated until the full excursion has traveled the minimum elevation
and depression specified in 3.10.1.1, as read on the elevation
counter.
4.7.1.2.2 (correction
With the correction counter
counter.
indicating "00 MILS", the correction counter knob shall be manually
rotated until the full. excursion has traveled the minimum and
maximum limits specified in 3.10.l.2, as read on the "+" and "-"
dials of the correction counter.
A c c-- r a c y .
u--
4.7.1.3
Set the correction counter to
Elevation readings.
4.7.1.3.1
M I L S " the elevation counter to indicate "200 MILS"
indicate " 0 0
depression.
With backlash removed for direction  of travel, rotate
elevation
fixture
11729722
untill
the
elevation
level
vial
bubble
f
O
the quadrant under test is centered within the thickness of a
graduation line.  Do not overtravel the center position.  Place
inspection aid 8658940 on Surface "A" shown on Drawing F11747194.
Measure and record the angular setting in the elevation fixture.
Repeat the above procedure with the elevation counter set to indicate