| MIL-R-23016(Wep)
3.2.9.10.3
(Continued)
width, shall have a minimum thickness of 0.025 inch$ and shall
be copper or brass metal straps, not braid. Connections made
with such bond straps shall have clean metal-to-metal contact.
3.2.9.10.3.1 Shock and Vibration Isolators:
Test samples shall be secured to mounting bases incorporating
shock or vibration isolator, if such mounting bases are used
in the installation. The bonding straps furnished with the
mounting base shall be connected to the ground plane. Where
mounting bases do not incorporate bonding straps, bonding straps
shall not be used in the test setup.
3.2.9.10.3.2 External Ground Terminal:
When an external terminal or connector pin is available for a
ground connection on the test sample, this terminal shall be
connected to the ground plane if the terminal is normally
grounded in the installation. If the installation conditions
are unknown, the terminal shall not be grounded.
3.2.9.10.3.3 Portable Equipment:
Portable equipment shall be tested while it is bonded to the ground
plane and also when it is not bonded to the ground plane. Portable
equipments that are intended to be grounded through a power cord
shall not be bonded to the ground plane by other means.
Power Supply Voltage:
3.2.9.10.4
The power supply voltages shall be within the tolerance specified
in the detail specification for the test sample. The voltages
shall be measured at the test sample terminals on the line
stabilization networks.
Arrangement and Operating Conditions:
3.2.9.10.5
The general arrangement of equipment, interconnecting cable
assemblies, and supporting structures shall be such as to simulate
actual installation and usage insofar as practicable. The front
surface of each unit shall be located 4 inches inch from the
64
|