| MIL-R-23016(Wep)
3.2.20.1
Input Power Connations:
Internal connections to the main power control of airborne
electronic equipment shall be in accordance with standard
MS25245.
3.2.29.2
Warm-up Time:
The time required for the equipment to warm up prior to opera-
tions shall be kept to a minimum and shall not exceed 10 minutes
under standard conditions and 15 minutes at extreme service
condition.
3.2.21
Service Conditions (Environmental):
The equipment shall be so designed and constructed that no
fixed part or assembly shall become loose, no moving or movable
part or assembly become undesirably free or sluggish in opera-
tion, no movable part or control be shifted in setting, position,
or adjustment, and no degradation be caused in the performance
below that specified in the individual specification during
operation or after storage in ambient conditions as follows.
3.2.21.1
Temperature:
The equipment shall be exposed to the temperature conditions
listed below. The ambient temperature within the specified
temperature ranges may remain constant for long periods and
may vary at a rate as high as 1C per second.
Operating:
3.2.21.1.1
The equipment shall operate at maximum duty cycle with rated
performance between -40C to +55C; and 30 minute emergency
operation at +70C at sea level.
3.2.21.1.2 Non-operating:
The equipment in a non-operating condition shall withstand long
periods of e xposure to the temperature extreme of -62C to
+85C.