REQUIREMENTS:
Contact data:
Load ratings:
High level (relay case grounded):
Resistive: 3.0 amperes at 28 V dc; 0.300 ampere at 115 V ac, 60 Hz and 400 Hz.
Resistive (relay case not grounded): 0.75 ampere at 115 V ac, 60 Hz and 400 Hz.
Inductive: 1.0 ampere at 200 mH inductive at 28 V dc (100,000 cycles).
Lamp: 0.200 ampere at 28 V dc.
Low level: 10 A to 50 A at 10 mV to 50 mV dc or peak ac.
Intermediate current: Not applicable.
Contact resistance or voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Not more than 5 percent of open circuit voltage.
After life: 0.100 ohm maximum.
Low level:
During life: 33 ohms maximum.
After life: 0.150 ohm maximum.
Contact bounce: 2.0 ms maximum.
Contact stabilization time: 2.5 ms maximum.
Overload (high level only):
Resistive: Two times rated, except grounded case ac.
Coil data: (See table I.)
Operate time: 8 ms maximum over temperature range with rated coil voltage.
Release time: 8 ms maximum over temperature range from rated coil voltage.
4