| ![]() MIL-R-39016/39F
Life test requirements:
High level: 100,000 cycles.
Low level: 100,000 cycles.
Part or Identifying Number (PIN): M39016/39-(dash number from table I).
Qualification inspection:
Qualification inspection and sample size: See table II.
TABLE II. Qualification inspection and sample size. 1/
Single submission
Group submission
50 units plus 1 open unit.
M39016/39-001
50 units plus 1 open unit.
One failure allowed.
One failure allowed.
Qualification inspection as
Qualification inspection as
applicable.
applicable.
M39016/39-018
Two units, qualification, Q1, also
shock, vibration, acceleration, terminal
strength and seal.
1/
The number of units required for qualification testing will be increased as required in Q5, table II, MIL-PRF-
39016, if the relay manufacturer elects to test the number of units permitting one or more failures. Prior to
performance of qualification inspection testing; the relay manufacturer shall preselect the sampling plan.