| MIL-R-48442(MU)
4.3.1 Submission of product.- Unless otherwise specified by
the contracting officer, inspection lot size, lot formation and
presentation of lots shall be in accordance with "Submission of Product"
provisions of MIL-STD-105.
4.3.2 Examination and test.- Examination and tests related to
Section 3 herein shall be performed on a single defect (individual
characteristics) basis in accordance with MIL-STD-105 and the sampling
plans specified in Tables I, II and III herein. Examinations and
tests for packaging, packing and marking shall be in accordance with
MIL-P-14232 and Section 5 herein. The tabulated classification of
defects in Tables I, II and III shall constitute the minimum inspection
to be performed by the supplier after first article approval and prior
to Government acceptance or rejection by item or lot.
TABLE I - CLASSIFICATION OF DEFECTS- 100% INSPECTION
No.
CHARACTERISTIC
REQUIREMENT TEST PROCEDURE
101.
Polarization of input terminal
3.6.1
4.6.3.1
Polarization of output terminal
102.
3.6.2
4.6.3.2
Polarization of battery terminal
103.
3.6.3
4.6.3.3
104.
Input potential
3.6.4
4.6.3.4
105.
Reverse polarity
3.6.5
4.6.3.5
Electrical shock
106.
3.7.1
4.6.4.1
107.
Input voltage surge
3.7.2
4.6.4.2
108.
Output current
3.7.3
4.6.4.3
109.
Output voltage
3.7.4
4.6.4.4
110.
Emergency Power Source
3.7.5
4.6.4.5
111.
Rise time
3.7.6
4.6.4.5
NOTE:
The tests in Table I shall be conducted at a temperature
between +70F and +80F.
4.3.3 Acceptance and rejection.- Rejected lots shall be screened
for all defective characteristics. Removal or correction of defective
units and resubmittance of rejected lots shall be in accordance with
"Acceptance and Rejection" as specified in MIL-STD-105.
4.4 Special sampling.
4.4.1 General.- Three assemblies shall be selected at random
as a special sampling from each 50 produced. The sample shall meet
the requirements and tests in Table II.
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |