MIL-R-5757/13H
PHYSICAL:
Enclosure design: Hermetically sealed.
Terminal strength: 3 0.3 pound pull.
Terminal twist test: Applicable to wire leads.
Sealed by welding: Applicable.
Dimensions and configuration: See figure 1.
Termination: See figure 1 and table I.
Weight: 1.1 ounces maximum.
Part or Identifying Number (PIN): See table I.
LIFE TEST REQUIREMENTS:
High level: 100,000 operations each at rated load.
Two relays per contact rating shall be tested, with rated loads on all contacts, except intermediate current.
For qualification inspection, life lamp load test not required.
Low level: Applicable (100,000 cycles).
Intermediate current: (50,000 cycles).
VERIFICATION (See table II):
Group A.
a. Group A2: 100 percent.
b. Dielectric withstanding voltage:
(1) Tests to be conducted at sea level rating only.
(2) Duration of application: 5-10 seconds at a 10 percent increase in the dielectric strength voltage.
7