| ![]() MIL-R-5757/23K
REQUIREMENTS:
CONTACT DATA:
Configuration: High-level 1/ characteristics, DPDT.
Arrangement: 2 form C.
Load ratings: 2/ (Relay case grounded)
Resistive:
10 amperes at 28 V dc.
3.0 amperes at 115 V, 60 Hz.
5.0 amperes at 115 V, 400 Hz.
Inductive:
6.0 amperes at 28 V dc.
2.0 amperes at 115 V, 60 Hz.
2.5 amperes at 115 V, 400 Hz.
Lamp:
1.0 ampere at 28 V dc.
0.5 ampere at 115 V, 60 Hz.
0.8 ampere at 115 V, 400 Hz.
Motor: 3/
3 amperes at 28 V dc.
1.5 amperes at 115 V, 60 Hz.
3 amperes at 115 V, 400 Hz.
Intermediate current: Applicable.
Contact resistance or voltage drop: Initial 0.1 V dc maximum.
_______
1/ High-level relays are not designated for use at low-level loads.
2/ The ac contact ratings are for single-phase power only.
3/ The relay shall be subjected to 50,000 cycles for making five times the rated motor load at rated voltage and
breaking the normal rated motor load. Duration of the inrush current shall be 0.07 0.02 second, after which it
shall be reduced to its rated motor load for the remainder of the on time. Cycling rate shall be 0.35 0.09
second on and 2 0.1 seconds off.
4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |