| MIL-R-5757H
4.6.8.4 Operate and release time (see 3.10.4). Operate and release time of all contacts shall be
measured using an oscilloscope or other acceptable means approved by the qualifying activity. Rated
voltage (or current) shall be applied to the coil. Contact load conditions shall be 6 V dc maximum or
peak ac at 10 mA maximum. The circuit shown on figure 6, or equivalent, shall be used. The operate
and release time shall be exclusive of contact bounce or contact stabilization time. Timing
measurements shall be made on all contact sets. Release time is not applicable to latching relays.