Measurements of coil resistance (or coil current) as applicable (see 3.1), and static contact
resistance as specified in 4.6.8.1 shall be taken at room temperature initially, then again after 125
hours 12.5 hours, 250 hours 12.5 hours, and 375 hours 12.5 hours and the values shall be
recorded.
d. After the relay(s) have been subjected to the coil life temperature cycles, measurements shall
then be taken at room temperature of dielectric withstanding voltage (4.6.7.1), insulation
resistance (4.6.6), static contact resistance (4.6.8.1), coil resistance (or coil current) (4.6.8.3),
operate and release time (4.6.8.4), and contact bounce (4.6.8.5.1).
e. Examination after test: As specified in 4.6.10e.
34
|