MIL-R-63997B(AR)
SAMPLING
REQUIRE-
INSP .
DEFECT
DEFECT
PROCEDURE
MENT
METHOD
No.
100%
3.7
Visual
Buffer  Retainer  Group.
23.
Burrs,  cracks  or  mutilation
of  buffer  retainer.
Buffer and Action
REMOVE:
Spring
100%
3.7
Visual
Burrs, cracks or
Buffer.
24.
mutilation  of  buffer.
100%
3.7
Visual
Distortion
Action  Spring.
25.
or  mutilation  of  action
spring
100%
3.7
Visual
Missing  lock
Pistol  Grip.
26.
washer,  cracks  or  mutilation
of  pistol  grip.
100%
3.7
Visual
Buttstock  Assembly.
27.
Cracks or mutilation
of  stocks.
100%
Visual
&
3.3.2.11
Buttstock  Assembly.
28.
Manual
*
Improper  assembly  of
stock.
Buffer
Assembly.
REASSEMBLE:
100%
3.3.2.12
*
Manual
Failure  of
Buffer  Group.
29.
buffer  to  function  through-
out  full  range  without
100%
3.7
Visual
Burrs,
Lower  Receiver.
30.
cracks or mutilation of
magazine  well  and  trigger
mechanism housing area.
18