| MIL-R-81128
(WEP)
X X "F (Plus Necessary Additional Notes)
FIRING LIMITS XX "F TO
PROPELLANT GRAIN MK XX
(If Applicable)
U S E IGNITER MK
XX
MOD XX
(If Applicable)
- E- -
S E PROPULSION - - - DATA SHEET - FOR FIRING -EXPIRATION DATE-
UNIT
-
-
-
-
-
-
-
-
-
-
--
C CONTRACT NO. XXXXXXXX
PROPELLANT LOT NO. X X X X X X X
P R O P E L L A N T CURE DATE
XXX
MFG: (OR LOADING ACTIVITY)
3.3.4
Type 4 - Igniter Marking. -Marking of igniters shall contain
the fol lowing minimum information arranged approximately as shown:
IGNITER MK XX MOD XX
SERIAL NO.
XXXXXXX
BUWEPS DWG. NO.
(Revision Letter)
XXXXXXX
CONTRACT NO.
XXXXXX
EXPLOSIVE LOT NO. XXXXXXX
EXPLOSIVE CURE DATE
xxx
MFG: (OR LOADING ACTIVITY)
4*
QUALITY
ASSURANCE
PROVISIONS
Responsibility for Inspection. -Unless otherwise specified in the
4.1
contract or purchase order, the supplier is responsible for the performance of aII
inspection requirement as specified herein. Except as otherwise specified, the
supplier may utilize his own facilities or any commercial laboratory acceptable to
the Government. The Government reserves the right to perform any of the inspections
set forth in the specification where such inspections ore deemed necessary to assure
supplies and services conform to prescribed requirements.
Classification of Inspection. -Inspection of the marking procedures
4.2
shall be classified as follows:
(a) Quality conformance inspection
4.3
Quality Conformance Inspection.
4.3.1
Visual Examination.
-Visually examine all parts and assemblies
to determine compliance with the proper marking procedures out lined in section 3.
5.
P R E P A R A T I O N FOR DELIVERY
5.1
Not Applicable
NOTES
6.
Not Applicable
6.1
|