| MIL-R-83407/3D
TABLE I. Dash number and applicable characteristics.
Pickup
Dropout
Contact
Rated coil
DC coil
Dash
voltage
voltage
arrangement
number 1/
voltage 2/
resistance
10%
maximum
minimum
form
V dc
V dc
V dc
Ohms
001
011
4.5
100
4.0
0.4
1A
002
012
12
500
9.6
0.9
1A
003
013
12
500
9.6
0.9
1C
004
014
4.5
87
4.0
0.4
1C
005
015
4.5
50
4.0
0.4
2A
006
016
12
300
9.6
0.9
2A
007
017
4.5
44
4.0
0.4
2C
008
018
12
250
9.6
0.9
2C
009
019
4.5
44
4.0
0.4
3A
010
020
12
250
9.6
0.9
3A
1/ Dash numbers -011 through -020 have gross leak and fine leak tests performed on
the switch capsule.
2/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise
the operation of the relay.
Electrical data:
Dielectric withstanding voltage (sea level): MIL-STD-202, method 301.
Test potential: 500 V rms, 60 Hz.
Test points:
Between case and all contacts connected.
Between all contacts connected and coil.
Between case and all other components.
Between electrostatic shield and all other components connected.
Insulation resistance: 10,000 megohms minimum.
Test potential: 90 V dc.
Test points: between contacts (switch open).
Capacitance (switch open):
Between contacts: 1 pF, maximum, measured at 1 kHz with shield guarded.
Between contacts and coil: 2 pF maximum.
6
|