| ![]() MIL-R-83726/12E
REQUIREMENTS:
Contact data:
Configuration 4PDT.
Life/load ratings (relay case grounded):
Amperes
Type of load
Life
28 V dc
115/200
(cycles)
1 and 3 phase
400 Hz
Resistive
100,000
10
10
Inductive
20,000
8
8
Motor
100,000
4
4
Lamp
100,000
2
2
Reduced current
400,000
2.5
2.5
resistive
Contact voltage drop:
Initial: 0.150 volt.
Intermediate current: Applicable in accordance with MIL-PRF-83536.
Contact bounce: 1 millisecond maximum.
Overload:
DC: 40 amperes.
AC: 60 amperes.
Rupture:
DC: 50 amperes.
AC: 80 amperes.
Input data:
Duty rating: Continuous.
Maximum voltage: 30 V dc.
Nominal voltage (over temperature range): 28 V dc.
Minimum voltage: 20 V dc.
Minimum voltage high temperature test: 21 V dc.
3
|