| ![]() MIL-R-83726/27K
TABLE IV. Field intensity levels.
RS103
Frequency
(volts/meter)
14 kHz to 200 MHz
20
200 MHz to 450 MHz
65
450 MHz to 1 GHz
20
1 GHz to 12 GHz
100
Environmental data:
Temperature range (operating): -70C to +85C. +171C nonoperating, 10 minutes. +200C,
nonoperating, 1 minute.
Altitude: 80,000 feet.
Shock:
G level: 50 g's.
Duration: 10 milliseconds.
Contact opening: 10 microseconds, maximum.
Contact closing: 1 microsecond, maximum.
Vibration (sinusoidal):
G level: 30 g's.
Frequency range: 10 Hz to 3,000 Hz.
Vibration (random): Applicable in accordance with MIL-STD-202, method 214, test condition 1B.
2
Power specter density: 0.4 g /Hz.
Frequency range: 50 Hz to 2,000 Hz.
Duration: 15 minutes each plane.
Vibration scan:
Frequency range: 5 Hz to 2,000 Hz.
Intensity: 0.01 inch double amplitude or 2 g's (whichever is less).
Acceleration: 15 g's.
Seal: Applicable to nonhermetically-sealed relays and hermetically-sealed (potted) relays.
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |