MIL-R-85320(AS)
d.
The high temperature test temperature shall be 93C
(200F) for Type I ejector units and 70C (158F)
for Type II ejector units.
4.6.8.3
Icing. The ejector unit shall be subjected to the Navy
and Air Force portion of the icing test.
4.6.8.4
Salt spray.
This test  shall be conducted under the
following conditions.
Store  release shall be effected by applying
non-pulsed 28 VDC: to the ejector unit.  Minimum operating voltage shall
be demonstrated by applying 20 VDC to the ejector unit.
4.6.8.5
Shock.
This test shall be conducted under the following
conditions.
The applied shock yield loads shall be specified in Table
IV. There shall be two shocks in each direction of the three axes shown
in the table for a total of 12 shocks.  The ejector unit shall be loaded
with a 113 kilogram (250 pound) store for the yield load tests.  After
the yield load test in each direction of the axis, stores shall be
manually released to ensure proper functioning of the ejector units.
The light load test shall not be conducted. Only yield loads shall be
applied during catapult and arrested loading tests.
4.6.8.6
Vibration.
This test shall be conducted in accordance
with the vibration test, Procedure I. A 450 kilogram (1000 pound) store
shall be used for loaded vibration.
4.6.8.7
Static.
This test shall be conducted with the following
conditions.
The design limit load shall be as specified in Table V.
The ejector unit shall be loaded to limit, yield and ultimate loads.
The combined loads and moments shall be applied to rigid simulated
stores of negligible weight (45 kilograms, 100 pounds maximum), such
that they act at each store center of gravity.
4.7  Qualification cross reference.
each
Table
VI  identifies
requirement in Section 3 and correlates the Section 4 paragraphs that
qualify it.
PACKAGING
5.
Ejector unit preservation and packaging.
Presentation
5.1
and packaging shall be in accordance with Level A, B, or C as specified
in MIL-STD-794, as specified in the contract, without the use of preser-
vation compound.
5.2
Packing.
Shipping containers shall contain one each
packaged ejector unit.
The container shall be suitable for Level A. B
or C as specified in MIL-STD-794.