| MIL-R-85523A(AS)
TABLE I.
Quality conformance inspection (see 4.5).
Inspection 1/
Procedure
Sampling 2/
Acceptance criteria
Visual examination
4.8.1.1
Every regulator
Reject units with critical
Regulator
defects
Accept 2.5 minor defects per
100 units
Dimensions
4.8.1.1.1
Inspection level
Reject defective units
II for minor
defects
Overload
Outlet
4.8.5.2
Every regulator
Reject defective units
Inlet
4.8.5.1
Every regulator
Reject defective units
Outlet pressure
4.8.2.2.2
Every regulator
Reject defective units
Steady state
pressure
Noise level
4.8.3
Every regulator
Reject defective units
Leakage
Body leakage
4.8.4.1
Every regulator
Reject defective units
Demand valve
leakage-outward
4.8.4.2
Every regulator
Reject defective units
Packaging
4.8.1.2
Inspection level
Accept 4.0 defect per 100
S-2
units
1/ The results of all inspections shall be identifiable by the assigned
serial numbers (3.5.1.3).
2/ The sample size shall be based only on the applicable sample size code
letter corresponding to the specified inspection level of MIL-STD-105.
19
|