MIL-R-85895 (AS)
TABLE V - Static Test Limit Loads
SIMULATED STORE CHARACTERISTICS
Longitudinal Dimension
Vertical Dimension
1
1
Store
Aft of Fwd Lug
Luq Center
From Top of Store
A
30 in.
15.0 in.
1.0
in.
B
16.125 in.
30 in.
15.0 in.
30 in.
11.93 in.
10.35 in.
c
2
COMBINED LIMIT LOADS AND MOMENTS ABOUT REFERENCE POINTS (STORE C.G.)
Pz
Py
Px
Mzz
Myy
Mxx
Vert-
Con-
Longi-
Yaw
Pitch
Roll
dition
ical
tudinal
Moment
Store
Side
Moment
Moment
267200
1
A
-23100
17300
66000
2750
57200
-20727
2
B
17272
-20727
-31622
114525
18630
3
C
-20070
17250
-31050
-43578
181575
2835
SIGN CONVENTION
+Px = Longitudinal Aft
+Mxx = Roll Clockwise Looking Forward
+Py = Side to Port
+Myy = Pitch Nose Up
+Pz = Vertical Up
+Mzz = Yaw Nose to Port
Note:
1.
The  centroid  of  the  loads  shall
act
at
a point in
accordance with these dimensions.
2.
Dimensions are in inch-pounds.