| MIL-S-1123E
UNDERWRITERS' LABORATORIES, INC. (UL)
Standard No. 1
-
Conduit, Flexible Steel.
Standard No. 4
-
Armored Cable.
Standard No. 6
-
Conduit, Rigid Metallic.
Wire and Cables, Rubber-Insulated.
Standard No. 44
-
Flexible Cord and Fixture Wire.
Standard No. 62
-
Wire, Thermoplastic-Insulated.
Standard No. 83
-
Outlet Boxes and Fittings.
Standard No. 514
-
Electrical Metallic Tubing.
Standard No. 797
-
(Application for copies should be addressed to the Underwriters
Laboratories, Inc., 207 East Ohio Street, Chicago, Illinois 60611; Walt
Whitman Road, Melville, Long Island, N. Y. 11749; or 1655 Scott Boulevard,
Santa Clara, California 95050.)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
Standard No. 70 (1965)-
National Electrical Code.
(Application For copies should be addressed to the National Fire
Protection Association, 60 Batterymarch Street, Boston, Massachusetts
02110.)
(Technical society and technical association specifications and standards
are generally available for reference from libraries. They are also dis-
tributed among technical groups and using Federal agencies.)
REQUIREMENTS
3.
3.1 First article.- Unless otherwise specified (see 6.2), before pro-
duction is commenced, a sample of the finished commodity procured under this
specification shall be submitted or made available to the contracting officer
or his authorized representative for approval in accordance with 4.2. The
approval of the preproduction sample authorizes the commencement of pro-
duction but does not relieve the supplier of responsibility for compliance
with all provisions of this specification. The preproduction sample shall
be manufactured in the same facilities to be used for the manufacture of
the production items.
*
3.2 Standard products.- Each item of equipment, including accessories,
shall be a current standard product of an established manufacturer: except
for such deviations from the manufacturer's commercial product as may be
required by the specification.
*
3.3 Standards ccmpliance.- Electrical components shall comply with the
following UL standards: fittings-Standard No. 514; armored cable-Standard
No. 4; flexible cord and fixture wire-Standard No. 62; thermo-plastic-
insulated wire-Standard No. 83; rubber insulated wire-Standard No. 44; and
conduit or tubing-Standards No. 1, 6, or 797, as applicable. The installation
of electrical components for each machine shall conform to NFPA Standard No.
70, the "National Electrical Code".