MIL-S-13303G(AR)
d.  the average angle from the vertical of the ejected smoke
assemblies shall not exceed 25 degrees.
The altitude shall be recorded for informational purposes.
3.5 Leakage test.  The sealed metal container shall show no
evidence of leakage when tested as specified in 4.5.3.
3.6 Container tear strip.  The container tear strip shall
comply with the requirements of MIL-C-10464 when tested as specified
in 4.5.4.
3.7 First article inspection.  This specification makes
provisions for first article inspection.  Requirements for the
submission of first article samples by the contractor shall be as
specified in the contract.
3.8  Workmanship.  All parts shall be fabricated and finished in
a thorough, workmanlike manner.  They shall be free of burrs, chips,
sharp edges, cracks, surface defects, dirt, grease, rust, corrosion
products and other foreign matter.  The cleaning method used shall
not be injurious to any part nor shall the parts be contaminated by
the cleaning agent.  All required markings shall be neat and sharply
defined.
QUALITY ASSURANCE PROVISIONS
4.
4.1 Responsibility for inspection and standard quality
assurance provisions.  Unless otherwise specified herein or in the
contract, the provisions of MIL-A-48078 shall apply and are hereby
made a part of this detail specification.
4.2 Classification of inspections.  The following types of
inspection shall be conducted on this item:
First Article Inspection.
a.
b.
Quality Conformance Inspection.
4.3 First article inspection.
4.3.1 Submission.  The contractor shall submit a first article
sample as designated by the Contracting officer for evaluation in
accordance with provisions of 4.3.2.  The first article sample shall
consist of items in sample quantities as indicated in Table 1.
See MIL-A-48078 and Table 1
4.3.2 Inspections to be Performed.
specified herein.
See
MIL-A-48078.
4.3.3 Rejection.