4.4 Quality conformance inspection.
4.4.1 Inspection lot formation.  Inspection lots shall comply
with the lot formation provisions of MIL-A-48078.  In addition~
inspection lots of simulators shall contain:
a.  Primers of one lot interfix number from one manufacture.
b.  Black powder from not more than one lot.
c.  Signals of one designation only.
d.  Star charge composition produced by one manufacturer
under one continuous set of operating conditions and which consists
of one or more batches that have been subjected to the same unit
chemical or physical mixing process intended to make the final
product homogeneous.
4.4.2 Examination.
(See MIL-A-48078).
a.  Sampling plans.  Unless otherwise specified in the
Classification of Defects and Test Tables, sampling plans for major
and minor defects shall be in accordance with MIL-STD-105,
Inspection Level II.