| ![]() MIL-S-17000N(SH)
TABLE VII.
Qualification inspection.
Requirement
Examination and tests
Test reference
paragraph
General examination
3.4 through 3.7.4
4.5
and 3.13
Circuit
3.6.24
4.6.1
Supply line voltage and
4.6.2
3.6.25
frequency variation
Transients
4.6.8
3.6.25
Dielectric withstanding voltage
4.6.3
3.6.29
Insulation resistance
4.6.4
3.6.29
Wire pull out tests
3.6.6 and 3.6.10
4.6.5
Enclosure
3.5.2.2.1, 3.5.2.2
4.6.9 and 4.6.1.1
and 3.5.2.4
Vibration
3.7.3
4.6.6
Equipment operating temperature
4.6.10
3.7.4
and humidity
Shock
4.6.7
3.7.2
4.3.1 Qualification sample. One sample switchboard section constructed
in accordance with the appendix will be required for qualification inspection.
4.3.2 Extension of qualification. Qualification of the sample switch-
board section specified in 4.3.1 will be extended to include qualification
approval for all types of switchboards covered by this specification.
4.3.3 Authorization for qualification inspection. Prior to authorization
of qualification inspection, drawings covering the overall mechanical assembly,
structural details, module assemblies, and panel-mounted assemblies of the
sample switchboard section shall be submitted to NAVSEA for review.
4.4 Quality conformance inspection.
4.4.1 Inspection. Each switching equipment shall be subjected to the
examination and tests shown in table VIII. Failure to conform to this speci-
fication for any examination or test shall be counted as a defect, and the
switching equipment shall be rejected.
TABLE VIII.
Quality conformance inspection.
Examination and tests
Requirement paragraph
Test reference
General examination
3.4 through 3.7.4 and 3.13
4.5
Circuit test
3.6.24
4.6.1
Supply line voltage and
3.6.25
4.6.2
frequency variation
Dielectric withstanding voltage
3.6.29
4.6.3
Insulation resistance
3.6.29
4.6.4
Wire pull out tests
3.6.6 and 3.6.10
4.6.5
Switchboard section alinement
3.5.2.4.1
4.6.1.1
55
|