| APPLICABLE
PARAGRAPH OF
SPECIFICATION
Note:
The above values do not allow for flywheed windage
losses, test stand drag, or inertia of the starter.
In order to determine compliance with this specifi-
cation, the test. equipment must be calibrated and
specific test results corrected accordingly. If
the acceleration specified for Phase C is not de-
veloped because of test stand drag torque, the test
s tand inertia load may be reduced or external power
may be applied to assist acceleration Lo cutout speed.
Time from end of Phase C to starter cutout shall not
exceed 15 seconds.
Rated Torque Calibration:
4.5.8
Minimum Output Drive Speed (RPM): 1100
Airflow, Max Lb per Min): 90
Overrunning: The starter output drive shall be driven
3.3.5
for 1 000 hours in a clockwise direction (viewed
4.5.9
Starter Drive Overrunning Speed RPM
Phase B
Phase C
Phase A
50 Hrs
200 Hrs
7000
4360
6800
Extreme Temperature Operation:
4.5.10
Ambient
Total
Total Press.
Temp
Temp
Consecutive Cyclical Operation: No. of cycles: 5
4.5.11
-
4.5. 12