MIL-S-19557/8(AS)
APPLICABLE
PARAGRAPH OF
SPECIFICATION
Extreme Temperature Operation:
4.5.10
Inlet Air Conditions
Ambient
Total
Total Press.
In. Hg A 0.5
Temp (F)
Temp (F)
-65
400
100
+160
800
100
Consecutive Cyclical Op eration: Number of Cycles: 5
4.5.11
Time (Minutes): 5
on
Sustained Motoring:
4.5.12
30
off
5
on
30
off
start
Vibration:  MIL-STD-810, Method 514, Procedure I, Curve F
(Parts 1, 2 and 3)
Slip Clutch Torque, Max (Lb-Ft): 1000
4.5.15.1
4.5.15.2
950 50
Applicable
Containment Tests:
4.5.18
HUB Containment Test: l
4.5.18.1
Inlet Air Pressure (PSIA): 49
Inlet Air Temperature(F): 345
Failure at No-Load:
4.5.18.2
Inlet Air Pressure (PSIA): 110
Inlet Air Temperature (F): 680