| ![]() MIL-S-25980A(USAF))
(b) Tests for Sample No. 2:
(4.6.1.1)
(1) Rumination of product
(4.6.19)
(2) weight
(4.6.3)
(3) Calibration
(4.6.2)
(4) Dielectric strength
(4.6.10)
(5) Immersion
(4.6.18
(6) Fuel resistance
(7) Endurance
(8)- Fluid dynamic loading
(4.6.3)
(9) Calibration
(4.6.4)
(10) Leakage
(4.6.20)
(11) Disassembly and inspecition
(c) Tests for Sample No. 3:
(4.6.1.1)
(1)
Examination of product
(4.6.19)
(2)
weight
(4.6.3)
(3)
Calibration
(4.6.2)
(4)
Dielectric strength
(4.6.7)
(5)
Vibration
(4.6.13)
(6)
Salt spray
4.6.11)
(7)
Mechanical shook
( 4.6.5)
(8)
Proof pressure
(4.6.6)
(9)
Burst pressure
(4.6.20)
(10)
Disassembly and inspection
ity conformance te sts.- Quality conformance tests shall consist of
4.4
individual tests and sampling tests, 4.4.1 and 4.4.2, respectively.
4.4.1 Individual test.- Each float switch shall be subjected to the following
tests, as specified under 4.6:
(4.6.1)
(a) Examination
(b) Dielectric strength
(4.6.2)
(c) Calibration
(4.6.3, 4.6.3.1, 4.6.3.6,
and 4.6.3.7)
(d) Immersion
(4.6.10)
4.4.2 Sampling tests.- Sample float switches shall be selected at random
from each inspection lot in accordance with the table titled "Sample size code
letters" of MIL-STD-105, Inspection level S-2, acceptance number zero for all
tests, and shall be subjected to the following teats, as specified under 4.6:
(a)
Room temperature endurance
(4.6.16.1)
(4.6.7)
(b)
Vibration
(c)
Roof pressure
(4.6.5)
(d)
Leakage
(4.6.4)
(e)
Burst pressure
(4.6.6)
(4.6.20)
(f)
Disassembly and inspection
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |