| ![]() MIL-S-48363 (PA)
4. 3.2 Examination. -The examinations listed in the follow-
ing subparagraphs shall be performed on inspection lots (see
4.3.1) of the components or assemblies designated in the appli-
cable paragraph headings. Inspection for critical defects (and
major defects, when so specified) shall be 100 percent. samp-
ling plans for major and minor defects shall be in accordance
with MIL-STD-105 except that continuous sampling plans in accor-
dance with MIL-STD-1235 may be used if approved by the Government.
Instead of applying the AQL's designated herein to the groups of
major and minor defects listed, the contractor may elect to apply
an AQL of 0.40 percent for each major defect and an AQL of 0.65
percent for each minor defect. When this method is elected, it
shall be applied to all of the major and minor defects listed in
the applicable sub-paragraph of this section, except where 100
percent Inspection is specified, and be documented as part of the
contractor's inspection system. Equipment necessary for the per-
formance of the inspections listed shall be in accordance with
4.3.4.
Fixture, Canister Holding (see dwg. 9280135).
4.3.2.1
|