TABLE I - Reliability p erformance requirements 
Operating parmeters 
Requirement 
Shelter 
Temperature* 
1. 
60F to 90F 
2. 
Airflow to shelter 
Minimum mean: 900 cfm 
850 cfm-I 
Minimum reading: 
Static pressure 
Vent mode set point: 
3. 
1(+0.1 or -0.2) iwg 
Minimum value all modes: 
mask alarm sound 
Maximum value all modes: 
2.0 iwg 
Airlock 
Airflow thru filter 
Minimum mean:  375 cfm 
1. 
Minimum reading:  300 cfm 
2. 
Static pressure 
Vent mode set point: 0.5 
(+0.1 or-O.2) iwg 
Minimum value all modes: 
0,3 iwg 
Filter and utilities unit 
1. 
Make-up airflow rate 
Minimum mean: 140 scfm 
Minimum reading: 135 scfm 
45 iwg maximum 
2. 
Inflation air pressure 
30 iwg minimum 
* Automatically controlled after manual mode selection. 
MTBF Criteria: 
(a) Overall system reliability - The overall system reliability for 
uated in accordance with test plan VII of MIL-STD-781. 