| MIL-S-63326(AR)
4.4 Quality conformance inspection
4.4.1 Inspection lot formation. Inspection lots shall comply with the
lot formation provisions of MIL-A-48078. In addition, each inspection lot of
S&A assemblies shall contain the following:
a. Detonators, micropiston actuators, MDF assemblies and lead
assemblies, each item from the same lot inter fix number from one manufacturer.
b. Explosive composition "PBXN-5" of one lot interfix number from one
manufacturer.
c.
Metal parts of one lot interfix number from one manufacturer.
4.4.2 Examination.
a. Sampling plans. Unless otherwise specified in the Classification
of Defects and Test Forms, sampling plans for major and minor defects shall be
in accordance with MIL-STD-105.
13
|